{"id":4602,"date":"2026-06-08T17:51:07","date_gmt":"2026-06-08T14:51:07","guid":{"rendered":"https:\/\/support.withsecure.com\/de\/?post_type=support_article&#038;p=4602"},"modified":"2026-06-08T17:51:07","modified_gmt":"2026-06-08T14:51:07","slug":"elements-connector-kann-protokolle-nicht-weiterleiten-fehler-nachricht-zu-lang","status":"publish","type":"support_article","link":"https:\/\/support.withsecure.com\/de\/support-articles\/elements-connector-kann-protokolle-nicht-weiterleiten-fehler-nachricht-zu-lang\/","title":{"rendered":"Elements Connector kann Protokolle nicht weiterleiten. Fehler: &#8222;Nachricht zu lang&#8220;."},"content":{"rendered":"<h3>Problem:<\/h3>\n<p> Elements Connector konnte die Protokolle nicht weiterleiten und gab die Fehlermeldung \u201eNachricht zu lang\u201c aus.<\/p>\n<h3>L\u00f6sung:<\/h3>\n<p> Dies tritt typischerweise auf, wenn versucht wird, ein UDP-Paket zu senden, das die maximal zul\u00e4ssige Gr\u00f6\u00dfe \u00fcberschreitet.<\/p>\n<p> UDP hat eine maximale Nutzdatengr\u00f6\u00dfe von 65.507 Byte (insgesamt 65.535 Byte \u2013 8 Byte f\u00fcr den UDP-Header \u2013 20 Byte f\u00fcr den IP-Header). Das SIEM-System hat jedoch wahrscheinlich ein niedrigeres Limit. Es wird empfohlen, f\u00fcr die Ereignisweiterleitung das TCP-Protokoll zu verwenden. Dieses ist insgesamt zuverl\u00e4ssiger. Die Konfiguration erfolgt im Profil des Elements Connectors.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Elements Connector kann Protokolle nicht weiterleiten. Fehler: &#8222;Nachricht zu lang&#8220;.<\/p>\n","protected":false},"template":"","support_article_product":[99],"class_list":["post-4602","support_article","type-support_article","status-publish","hentry"],"acf":{"source_foreign_id":"000015206","source_version":2,"source_system":"salesforce","source_date_updated":"2026-06-08 14:51:07","import_hash":"fb01807f24a6adad83d38f3a97801e0af9bf438a","vanilla_article_id":32705,"vanilla_url":"https:\/\/community.withsecure.com\/en\/kb\/articles\/32705-elements-connector-unable-to-forward-logs-with-error-message-too-long","vanilla_kb_id":30,"vanilla_category_id":102,"machine_translated":false,"reactions_helpful_yes":0,"reactions_helpful_no":0},"_links":{"self":[{"href":"https:\/\/support.withsecure.com\/de\/wp-json\/wp\/v2\/support_article\/4602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.withsecure.com\/de\/wp-json\/wp\/v2\/support_article"}],"about":[{"href":"https:\/\/support.withsecure.com\/de\/wp-json\/wp\/v2\/types\/support_article"}],"wp:attachment":[{"href":"https:\/\/support.withsecure.com\/de\/wp-json\/wp\/v2\/media?parent=4602"}],"wp:term":[{"taxonomy":"support_article_product","embeddable":true,"href":"https:\/\/support.withsecure.com\/de\/wp-json\/wp\/v2\/support_article_product?post=4602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}