Support articles

Endpoint Protection

  • WithSecure Elements EPP for Computers installation fails in a Windows 8 computer with error "This version of Windows is not supported"

    Read more
    Issue:

    WithSecure Elements EPP for Computers installation on a Windows 8 computer, fails with error "Check System Requirements, This version of Windows is not supported, please make sure you have the right operating system and service packs installed."

    Resolution:

    Only Microsoft Windows 7, 8.1 and 10 (all 32-bit and 64-bit editions) are supported for WithSecure Elements EPP for Computers installation. Proceed to upgrade your Microsoft Windows 8 operating system to version 8.1 before installing the F-Secure product.

  • Why is the Software Updater status missing for Elements Agents on Mac in the Elements EPP portal?

    Read more
    Issue:

    Why is the Software Updater status missing for Elements Agents on Mac in the Elements EPP portal?
    Why is the Software Updater status doesn't working for Elements Agents on Mac?

    Resolution:

    The Software Updates status is displayed in the Elements EPP portal only if the 'Scan for missing Software Updates' operation has been executed. If the Software Updater does not perform the check for updates via the Elements EPP portal, there will be no information to report.

    In this case, it is most likely that the scanning was not yet performed on the device(s).

    You can manually trigger the scanning by creating an Automated Task in the Elements Security portal. Follow the steps below to configure and run the scan:

    Steps to Create an Automated Task:

    1. Log in to the Elements Security Portal: Navigate to the portal and access the Security Configuration settings.

    2. Select the Security Configuration Profile:

      • Go to Security Configuration > Profile.

      • Click on the Mac tab.

      • Select the profile (e.g., text_Mac) that you want to update.

    3. Enable Automated Tasks:

      • In the left-hand pane, select Automated Task.

      • Turn on the feature if it is not already enabled.

    4. Configure the Scan Task:

      • Set the task type to Scan for missing Software Updates.

      • Define the schedule for the scan using a CRON expression. (Refer to the help icon next to "The list of automated task" for CRON syntax guidance.)

    5. Save and Publish:

      • Click Save to confirm the changes.

      • Publish the profile to apply the new settings to the devices.

    6. Monitor the Status:

      • Once the task is configured and executed, monitor the Elements EPP portal to check if the Software Updates status is now displayed.

    Additional Notes: Ensure that the device(s) in question are connected to the internet and synchronized with the Elements EPP portal to successfully receive and execute the automated task.

     

  • Why is the Password for uninstallation shown as an asterisk in the Elements Endpoint Protection Portal device profiles?

    Read more
    Issue:

    Why is the Password for uninstallation shown as an asterisk in the EPP for Computers and EPP for Servers profiles? How can an administrator view the password for uninstallation for devices which have Elements Agent installed? 

    Resolution:

    The F-Secure Elements Endpoint Protection Portal does not store the uninstallation password in cleartext for security reasons. This is so that the password cannot be viewed by anyone, even by F-Secure. If the administrator has forgotten the uninstallation password, they can create a new one. 

  • When creating a company account, Elements Endpoint Protection portal displays "Invalid subscription key. TX-ID: 0000-" error

    Read more
    Issue:

    When trying to create a company account in the Elements Endpoint Protection portal, there is an error "Invalid subscription key."
     

    Resolution:

    There are multiple situations that can cause this error message:

    • You are using the incorrect subscription key (there can be a typo).
    • You are using the subscription key in the incorrect Elements Endpoint Protection portal. Please check your license certificate for the correct portal address.
    • Subscription key has already been added to your Elements Endpoint Protection company account. Please do a password reset to try to login to your account. 
    • You have a Partner Managed subscription and you do not need to create a company account since one has already been created for you automatically. Only Company Managed subscriptions require you to manually create your company account.  Contact your reseller partner if you want to have your own administrator account for your company account. You can view your license certificate to see if your subscription is Partner Managed or Company Managed
  • Why is the Browsing protection extension name still "Browsing protection by F-Secure" for Elements products

    Read more
    Issue:

    Why is the Browsing protection browser extension or add-on still named "Browsing protection by F-Secure" for Elements Endpoint Protection products?

    Resolution:

    WithSecure products will switch to using the "Browsing Protection by WithSecure" browser extension in early March 2024. You can read more about this change from the Elements Endpoint Protection changelog Community post.

    If you are using GPO to force extension usage on user's devices, you can change the extension ID in your GPO settings.  In that case the switch to the new extension should be silent. If you aren't using GPO or MDM, for Google Chrome and Microsoft Edge the extension will be switched automatically and the user will see a confirmation window: "do you want to enable this extension?". The end-user needs to agree to take the extension in use.

  • What happened to WithSecure Elements EPP for Servers reboot / restart options for Software Updater in the profiles?

    Read more
    Issue:

    WithSecure Elements EPP for Servers no longer has reboot / restart options for Software Updater, how can I reboot my server automatically after installing the updates?

    Resolution:

    The "Force restart" and "Restart after installation" options are no longer shown in the Software Updater profile tab under the EPP for Servers profiles because it no longer uses these options. Software Updater no longer forces a reboot on servers, giving more control for admins to schedule server maintenance. 

    The Automated tasks feature has a Force restart if required task available. 
     

  • When trying to create an offline MSI installer for Elements Endpoint Protection using the FSMSI tool, user receives error: "FsMsiTool is not recognized as an internal or external command." 

    Read more
    Issue:

    When trying to create an offline MSI installer for WithSecure Elements EPP for Computers or for Servers using the FSMSI tool, user receives error: "FsMsiTool is not recognized as an internal or external command."

    Resolution:

    You have to execute the FSMSI tool command from the directory where the tool is saved to or else you will get the error. Using the command prompt, navigate to the folder where you have saved the tool and then run the command mentioned in this help guide.

  • Why is a customer company or a subscription key not visible in the Elements Security Center in a reseller partner's account?

    Read more
    Issue:

    Reseller partner has sold a subscription to a customer. However, when the reseller partner check in the Elements Security Center, they are unable to see / view the customer company or the subscription key / code under the reseller partner's solution provider/service partner account.

    Resolution:

    Make sure that you have logged in to the correct Elements user with the solution provider/service partner rights. If anyone else in your company has an  Elements user too, they can verify Elements user access level on the Management > Organization settings > Endpoint Protection Accounts page in the Endpoint Security Center. If you are the only Elements user, you may contact your WithSecure sales contact for assistance.

    If you have logged in using the correct Elements user but are unable to see the customer company in the scope drop-down menu on your account, make sure that you have sold the Endpoint Protection product as Partner Managed and not Company Managed. If the product has been sold as Company Managed, neither the customer company nor the subscription will be shown in the reseller partner's account.

    There is also a risk that something has gone wrong with the order itself. If the order provisioning fails it will be left pending a manual correction. These are done regularly and if this occurs, your order should become visible at the latest within the next business day (unless further information is required from you in which case you would be contacted). 

    If you have accidentally purchased a Company Managed asset, and want to change it to be Partner Managed, or if you want to verify the state of your order, contact our Order Services team or your WithSecure Sales contact.

    If you are unable to reach your WithSecure Sales contact, contact WithSecure Customer Care: https://www.withsecure.com/en/support/contact-support/email-support

    Note: If customer has only Business Suite products, such as Client Security or Server Security, these products are not part of the Elements portfolio and therefore do not use the Elements Security Center.

  • The message "Policy does not require the password" is seen next to the user properties under the device status in the Elements Security Center

    Read more
    Issue:

    * The message "Policy does not require the password" is seen next to the user properties under the device status in the Elements Security Center. What goes wrong with the user on the device in this case?
    * The issue "Device at risk due to accounts for which password is not required" is showing up in the dashboard in the Elements Security Center. How can I get this fixed?

    Resolution:

    The message "Policy does not require the password" is showing up under the device status if the local user is not subject to the password policy regarding the length of password. We do not have the option to hide this issue in the portal without fixing this.

    In this case, the local user can have a shorter password than it is required, or it may even have no password at all. You need to check and tweak the UserAccountControl attribute of the user to remove the flag "UF_PASSWD_NOTREQD" if it is found.

    You may run the following command to validate the flag of the local user:

    net user <username>

    If password required flag is "NO" for the user, run the following command to fix it:

    net user <username> /passwordreq:yes

    We would recommend to get this fix soon as possible to avoid any password leak and other potential issues.

  • Unable to access WithSecure Elements portal from the old f-secure.com address

    Read more
    Issue:

    Unable to access WithSecure Elements portal from the old elements.f-secure.com or emea.psb.f-secure.com addresses. 

    Connection ends in errors such as: 

    • Hmmm… can't reach this page. (Edge)
    • This site can't be reached (Chrome)
    • Hmm. We're having trouble finding that site (Firefox)
    Resolution:

    As announced early in 2023, we have changed all of our domain names used by WithSecure Elements to use the withsecure.com address space. Until recently, the old elements.f-secure.com redirected to elements.withsecure.com, but now that redirection has been removed as we no longer have any influence on f-secure.com.

    Please always use https://elements.withsecure.com/ to access the Elements Security Center