  • How to remote uninstall Elements EPP for Mac from Elements Security Center portal?

    Read more
    Issue:

    How to do a remote uninstall (silent) of Elements Agent for Mac from the Elements Security Center portal?  There is no "uninstall" operation listed in the Actions menu when a MacOS device is selected on the Environment > Devices page. 

    Resolution:

    Remote uninstallation from Elements Security Center is currently available for Windows devices only, so on macOS the agent has to be removed with a script pushed through your MDM or remote management tool (for example Jamf, Apple Remote Desktop or SSH). This can be done fully without user interaction as follows.

    1. Deploy an MDM configuration profile that allows the WithSecure system extension to be removed. In the System Extensions payload add Team ID V928P8X763 with the extension com.withsecure.wsagent.wssystemextension both under Allowed System Extensions and under Removable System Extensions. This profile is what lets the extension be deactivated without a logged-in user approving it.
    2. In Elements Security Center, make sure the Mac profile assigned to the devices allows the user to uninstall the product (Profiles > For Mac > General settings). If this is disabled, the uninstall script will fail.
    3. Push a script that runs as root and executes these two commands in this order:
    /Applications/WithSecure/WithSecure\ Agent.app/Contents/MacOS/wsagent --deactivate-system-extension
    /Library/WithSecure/bin/uninstall_MacProtection
    4. Once the agent is removed, delete the device from the Devices page in Elements Security Center to release the licence.

    If the subscription has already expired and the profile can no longer be changed, the uninstall restriction can be lifted by deleting the file /Library/WithSecure/fsmac/sysconfig/.no_uninstall before running the script. 

  • Add new device button missing under Devices view in Elements portal

    Read more
    Issue:

    The "Add new device" option missing on the Environment > Devices page in the Elements Security Center portal when the three dots are clicked. Why is the button missing? 

    Resolution:

    If the Add new device option is missing on the Elements Security Center portal's Environment > Devices view in the Elements Security Center Portal when you click on the three dots, there are a few reasons why it can be missing:

    • You are missing the full management rights for Elements Endpoint Protection
    • You do not have valid licenses for the product you are trying to add
    • If you are a partner user, you have the wrong level selected from the scope-selector

    You are missing the full management rights for Elements Endpoint Protection

    Make sure that your user account has full editing rights for Endpoint Protection:

    1. Log in to the Elements Security Center portal
    2. Navigate to the Management > Organization Settings > Security Administrators page 
    3. Check the Endpoint Protection column for your user account and make sure that you have the correct rights

    If you do not have the full editing rights for Endpoint Protection, ask a colleague to add the rights for you or if you have a Partner Managed subscription you can contact your partner to have the rights added. 

    You do not have valid licenses for the product you are trying to add

    The Add new device button can be missing if you do not have any relevant licenses attached to your company account. Make sure from the Management > Subscriptions page that you have valid licenses for one of the following:

    • Elements EPP for Computers or Servers
    • Elements EPP for Mobiles 

    If you are a partner user, you have the wrong level selected from the scope-selector

    If you are a partner, you need to select the customer company level from the Scope-selector drop-down menu. The Add new device button is not visible on the partner level because the partner level doesn't include any subscriptions.  The scope-selector is the drop-down menu shown in the top-left corner of the Elements Security Center portal. 
     

     

  • Elements Endpoint protection Connection Control activates by itself automatically in Mozilla Firefox

    Read more
    Issue:

    When opening the browser, Elements Endpoint Protection Connection Control activates by itself automatically in Mozilla Firefox without the user entering a banking page. When Connection Control is active, many websites are blocked unnecessarily. 

    Resolution:

    If Connection Control (Banking Protection) automatically activates itself when you open Mozilla Firefox, it can be because among the most visited pages in a "new tab" view there is a banking website listed. Firefox preloads these pages and it can trigger the protection. 

    Try to remove all banking related pages from the view when you open a new tab and then restart the browser to confirm if the issue still persists.

  • Is it possible with the Elements Endpoint Protection Device Control to allow specific type of network adapters?

    Read more
    Issue:

    Is it possible with Elements Endpoint Protection Device Control feature to block all network adapters, but allow a specific type, group or class of network adapter, such as virtual network adapters or specific vendor's network adapters?

    Resolution:

    Device Control can block devices based on their Hardware ID, Compatible ID or Class GUID (https://community.withsecure.com/en/kb/articles/5525-how-device-control-block-devices)

    To allow or block all network adapters, a Class GUID rule for network adapters is required.: 

    1. Log in to Elements Security Center Portal 
    2. Go to the Environment > Profiles page
    3. Select the profile which is in use on the devices
    4. Go to Device control settings
    5. Enable device control 
    6. In Device access rules, click Add rule 
    7. Add {4d36e972-e325-11ce-bfc1-08002be10318} in the Hardware ID field 
    8. In Access to device, select either Block or Allow depending on your use case
    9. Click Save profile

    In this case the {4d36e972-e325-11ce-bfc1-08002be10318} is the Class GUID for all network adapters: https://docs.microsoft.com/en-us/windows-hardware/drivers/install/system-defined-device-setup-classes-available-to-vendors?redirectedfrom=MSDN

    If you want to allow only a specific vendor's network adapters, you can allow the network adapter's Compatible ID. The Compatible ID rule is created by following the same steps as for the Class GUID, except the Compatible ID is added to the Hardware ID field.

    If the device is not blocked, the Hardware ID, Compatible ID and Class GUID can be viewed from the Elements Endpoint Protection Portal from the device's Connected devices list :

    1. Log in to Elements Security Center Portal
    2. Go to the Environment > Devices page
    3. Select device 
    4. Go to the Connected devices tab
    5. Click on the arrow on the left to view ID details

    The Compatible ID can also be acquired locally from the device by following these steps:

    1. Open Device Manager
    2. Right-click device > Properties
    3. Go to Details tab
    4. Select property as Compatible ID

    If Compatible ID property is not selectable, then the device has none. 

  • What is the data retention for audit logs and security events in the Elements portal?

    Read more
    Issue:

    What is the data retention for audit logs and security events in the Elements Security Center portal? How long time are the audit logs and security events stored in the portal before they are automatically removed or cleared? 

    Resolution:

    For security events are available for a limited period of time dependent on their severity.

    • Max 7 days for Info
    • Max 6 months for Attention
    • Max 13 months for Action Needed

    For audit log sas of now there is no retention period. 

  • Is it possible to reset or delete all events from the Security Events page in the Elements Portal?

    Read more
    Issue:

    Is it possible to reset, delete or remove all or some events from the Events > Security Events page in the Elements Security Center Portal?

    Resolution:

    It is not possible to reset, delete or remove events from the Events > Security Events list in the Elements Security Center portal. The info alerts are stored for 7 days, warning alerts for 6 months and critical alerts for 13 months.

    Once the event has been automatically removed from the portal, it cannot be recovered. 

  • When will a device shown on the "Manage removed devices" list be automatically removed from the list?

    Read more
    Issue:

    When will a device that is shown on the Elements Security Center portal's Environment > Devices > Manage removed devices  list be automatically removed from the list?

    Resolution:

    If the Elements Agent is uninstalled, then the device will be removed from portal after 6 months from the date it was uninstalled. 

    If the device is manually removed from the portal (but not uninstalled), then the device will be removed from the list after 12 months from the date it was removed.

  • Elements EPP doesn't scan USB drive when "Action when USB storage device is plugged in" is set to scan USB

    Read more
    Issue:

    Elements Endpoint Protection doesn't scan a USB drive when "Action when USB storage device is plugged in" is set to:

    • "scan USB and show results to user" 
    • "Silently scan USB" 
    • "Force scan USB and show result to user" 
    • "Ask user to scan USB" 
    Resolution:

    Make sure that the USB drive that you have connected to the computer is a USB thumb drive or an SD card. If it is an external HDD, it will not be scanned even if it would use a USB connection.

    This is expected behavior since the "Action when USB storage device is plugged in" feature uses internal Windows device flags which tells Windows which type of device is connected. It's not using device ID or hardware ID.

     

  • I receive error "Failed to save profile TX-ID: 0000-XXXXXXXX" when trying to reconfigure a setting via the Profile Editor in the Elements Endpoint Protection portal

    Read more
    Issue:

    Error "Failed to save profile TX-ID: 0000-XXXXXXXX" when trying to edit or modify a setting with the profile editor in the Elements Security Center portal. 

    Resolution:

    If you receive a "Failed to save profile" error when saving an Elements profile, the issue is most of the time caused by a invalid setting in the Elements profile. Try to clone the profile and then make your modification and then try to save the newly cloned profile. If you receive the same error, you can either try to create a completely new profile or try to fix the original profile.

    If you want to try to fix the original profile, check in the profile's navigation menu on the left side if there is a red stripe on the left side of any of the settings pages. That red stripe indicates that there is an invalid setting that you need to either remove or modify. 

    If no red stripe is shown, then the issue is very likely due to a custom Application Control or Automated Tasks rule. Try to remove Application Control rules and Automated Tasks one by one and try to save each time you have removed a rule. Once you have found out which rule is causing the issue, you can remove or modify it and then save the profile. 

     

  • Elements Mobile Protection high battery usage on Android device

    Read more
    Issue:

    Usage time of the Android mobile is reduced by 80% as long as Elements Mobile Protection is installed.

    Resolution:

    Elements Mobile Protection will always do a full scan of the system when the Android mobile device is restarted. If you restart the device daily or very often, the Elements Mobile Protection application can drain a significant amount of battery. 

    Also check that you do not have scheduled scanning set to do a daily scan:

    1. Log in to the Elements Security Center portal
    2. Navigate to Security configurations > Profiles page
    3. Go to the for Mobile tab
    4. Click on the profile that is in use on the device
    5. Go to the Malware protection settings page
    6. Scroll down to the Scheduled scanning section
    7. Make sure that the Scan frequency is not set to Daily
    8. Click Save profile

     

    If battery usage is still very high after checking the scanning settings, you can try to see if reinstallation of the app fixes the issue.