  • Business Suite Server Security or Elements Endpoint Protection for Servers Software Updater does not reboot the system after installing an update, and system reboot is required to complete the installation

    Read more
    Issue:

    I have noticed that Software Updater does not reboot the system automatically after installing an update, and system reboot is required to complete the installation. Why is this happening?

    Resolution:

    WithSecure server solutions are designed to not reboot a server automatically after Software Updater has finished installing an update (and if system reboot is required to complete the installation), despite you have set the Software Updater reboot configuration to either "Ask user" or "Force reboot".

    This is an expected behavior for WithSecure server products. We do not want to trigger a system reboot, to avoid potential interruption on a server.

    You need to reboot the server manually, to complete the update installation.

  • When exporting report in Partner Portal user gets error: "An internal error has occurred"

    Read more
    Issue:

    When exporting a report on the Solutions > Reports page in Partner Portal user gets error:

    "An internal error has occurred - An error occurred while processing your request. Our support team has been notified of the issue. If you have additional information that you believe may be helpful as we resolve the problem, please feel free to contact Salesforce Support. Provide the URL of the page you were trying to access, any error ID that appeared on the page, and any other relevant information. We apologize for the inconvenience. "

    Resolution:

    This issue can happen if your Partner Portal language is set to any other language than English. 

    Here are the steps how a Partner Portal admin user can change the portal language for a user:

    1. Log in to the Partner portal 
    2. Open the drop-down menu by clicking the blue arrow beside your user name in the top-right corner 
    3. Go to Account Management 
    4. Click Edit Member 
    5. Select the member from the list and click Next 
    6. Select English from the Language drop-down menu
    7. click Save 

     

  • Error "an error occurred while loading contact information" when renewing or amending a subscription in Partner Portal

    Read more
    Issue:

    Error: "an error occurred while loading contact information" when renewing or amending a subscription in the WithSecure Partner Portal.

    Resolution:

    If you get this error when trying to amend or renew a subscription in the Partner Portal, you need to make sure that the end-customer company has at least one contact. Navigate from the menu on the top to Sales > Accounts and click on the customer for whom you are trying to make an order. In the Customer Overview tab you will find the Contacts section. Click on the New button and add the contact information.

    After the customer has at least one contact, try to make the order again. 

  • How do I submit a large diagnostic file (WSDIAG) via WithSecure Customer Support's Dropzone?

    Read more
    Issue:

    How do I submit a large diagnostic file (WSDIAG) via WithSecure Customer Support's Dropzone?

    Resolution:

    Our Customer Support may ask you to create and send a diagnostic file (WSDIAG) for further investigation.

    If the file size of your diagnostic file is larger than 10MB, it is too large to send by email.

    However, you can upload the file to our Customer Support's Dropzone by following the instructions below. 

    Make sure that you have a case number before submitting the file, which is stated in the email sent by our Customer Support.

     

    1. Access to https://withsecure.sendsafely.eu/dropzone/technicalsupport using your browser, and a Secure File Drop webform is displayed
    2. Enter your Case Number and Email Address on the webform
    3. Click on Drag files here or click to add a file and select your file (or drag and drop it there)
    4. Click on Open button and wait until the file uploading is completed
    5. Click on Submit button to proceed with the submission
    6. Copy the Submission ID number shown on the page
    7. Reply to the email sent by our Customer Support to inform us that you have now uploaded the WSDIAG file and share its Submission ID number